Công ty Vinafloor cung cấp sàn nâng hoàn thiện HPL cao cấp cho giải pháp sàn nâng ngân hàng, văn phòng, sàn nâng nhà máy, phòng sạch, phòng lạnh, sàn vinyl chống tĩnh điện...
Sàn nâng HPL
As a general guide, selection of the appropriate system can be by general description of the area. However, the guide chart shown below is based upon Tate's experience to date and it is recommended that due consideration is given to the specifications of the project, i.e. anticipated raised floor loadings and height requirements in every case.
Theo tiêu chuẩn của TAKO
Product Advantages
Understructure System
Corner Lock System - suitable for low height and offers easy and fast installation
Rigid Grid Bolted Stringer System - specifically used in heavy loads environment. Our wide range of pedestals are capable to cater up to FFH 1.5 meter. Additional bracing can be added for extra rigidity.
Access Floor Systems
System Selection Guide
As a general guide, selection of the appropriate system can be by general description of the area. However, the guide chart shown below is based upon Tate's experience to date and it is recommended that due consideration is given to the specifications of the project, i.e. anticipated raised floor loadings and height requirements in every case.
Building Type | Std Panel | Heavy Duty Panel | U/S | Wire/Cable FFH | Wire/Cable/ Air FFH | Coverings |
---|---|---|---|---|---|---|
General Office | ConCore® 1000; Woodcore | ConCore® 1250 | PosiLock® | 2 1/2" - 6" | 12" - 18" | Carpet Tile; PosiTile®; Specialty Coverings |
Service Corridors | ConCore® 1250 | ConCore® 2000; ConCore® 2500 | Combination Bolted Stringer & Cornerlock | 2 1/2" - 6" | 12" - 18" | HPL with Integral Trim |
Computer Rooms | ConCore® 1000; All Steel 1250; Perf 1000; WC5000 | ConCore® 1250; Perf 1250 | Bolted Stringer | N/A | 12" - 24" | HPL with Integral Trim |
Internet Data Center/ Telecom Switch | ConCore® 1000; All Steel 1250; Perf 1000 | ConCore® 1250; Perf 1250 | Bolted Stringer | N/A | 12" - 24" | HPL with Integral Trim |
Electrical/ Telecom Closet | ConCore® 1000; All Steel 1250 | ConCore® 1250 | Bolted Stringer | 6" - 12" | N/A | HPL with Integral Trim |
Lobbies | ConCore® 1500 | ConCore® 2000; ConCore® 2500 | Combination Bolted Stringer & Cornerlock | 2 1/2" - 6" | 12" - 18" | Carpet Tile; PosiTile®; Specialty Coverings |
Casinos | ConCore® 1500 | ConCore® 2000; ConCore® 2500 | Combination Bolted Stringer & Cornerlock | 2 1/2" - 6" | 12" - 18" | Carpet Tile; PosiTile®; Specialty Coverings |
Educational | ConCore® 1000; Woodcore | ConCore® 1200 | PosiLock® | 2 1/2" - 6" | 12" - 18" | Carpet Tile; PosiTile®; Specialty Coverings |
Print Rooms | ConCore® 1500 | ConCore® 2000; ConCore® 2500 | Bolted Stringer | 2 1/2" - 6" | 12" - 18" | Vinyl Tile; Rubber Tile |
Call Centers | ConCore® 1000; Woodcore | ConCore® 1250 | PosiLock® | 2 1/2" - 6" | 12" - 18" | Carpet Tile; PosiTile® |
Trading Floors | ConCore® 1250 | ConCore® 1500 | Bolted Stringer | 6" - 12" | 12" - 24" | Carpet Tile; PosiTile® |
Retail | ConCore® 1000; Glass Panels | ConCore® 1250; Glass Panels | PosiLock® | 2 1/2" - 6" | 12" - 18" | Vinyl; Specialty Coverings |
Clean Room/ Electronic; Assembly Area; MRI Rooms | Aluminum 1250 | Aluminum 3000 | Bolted Stringer | 6" - 12" | 12" - 24" | HPL with Integral Trim; Conductive Tile |
Theo tiêu chuẩn của TAKO
- Free standing for easy & fast installation and access
- Electrostatic dissipative: drain static charge slowly to avoid charge built-up on the panel surface
- Easy maintenance & durable surface cover. Resistance to many chemicals that are found in industrial environments
Understructure System
Corner Lock System - suitable for low height and offers easy and fast installation
Rigid Grid Bolted Stringer System - specifically used in heavy loads environment. Our wide range of pedestals are capable to cater up to FFH 1.5 meter. Additional bracing can be added for extra rigidity.
CONDUCTIVE VINYL | ||||||||||||
1. | Thickness | 2.0mm | ||||||||||
2. | Electrical Resistance | Between two electrodes 25,000 to 1,000,000 ohms Floor to ground greater than 25,000 oh | ||||||||||
3. | Static Generation | Less than 100 volts with conductive footwear per AATCC 134 at 20% relative humidity | ||||||||||
4. | Static Decay | 5,000 volts to zero in less than 0.03 seconds | ||||||||||
5. | Fire Resistance | Critical Radiant Flux :> 1.08 w/cm2 Flame Spread :< 75 Smoke Density :< 450 | ||||||||||
6. | Abrasion Resistance |
|
ANTISTATIC HPL | ||
1. | Thickness | 1.2 / 1.5mm |
2. | Electrical Surface Resistance | GJB 300 7-97 1x10^6 - 1 x 10 ^10 3. |
3. | Static Generation | SJ . T10694-1996=V<100v data-blogger-escaped-td=""> |
4. | Flammable Fire Hazards | GB4609-8-1 FV-1 (<30s data-blogger-escaped-td=""> |
5. | Abrasion Resistance Test Result | (>350 cycles) 2000 - 2250 cycles |